FW 07.00.00/HAFM SW 08.06.00 McDATA Sphereon 4300 Fabric Switch Installation and Service Manual (620-000171-010, April 2005)
Event Code Tables
A-35
Event Code: 583
Message: Loss of signal or loss of synchronization.
Severity: Major.
Explanation: An attached OSI server recognized a loss-of-signal condition or a loss-of-synchronization condition that persisted
for more than the specified receiver-transmitter timeout value (R_T_TOV).
Action: A LIR is generated and sent to the attached server using the reporting procedure defined in T11/99-017v0 (OSI).
If fault isolation at the server does not detect a failure, the problem may be due to a port failure. Go to MAP 0000:
Start MAP on page 3-6 to perform fault isolation.
Event Data: Refer to the T11/99-017v0 document for the specific link incident record format.
Distribution: Switch Management Server Host
SANpilot
Event Log
System
Error LED
Event Log E-Mail Call-Home Sense Info Link Incident
✔
Event Code: 584
Message: Not operational primitive sequence received.
Severity: Major.
Explanation: An attached OSI server received a not-operational primitive sequence (NOS).
Action: A LIR is generated and sent to the attached server using the reporting procedure defined in T11/99-017v0 (OSI).
If fault isolation at the server does not detect a failure, the problem may be due to a port failure. Go to MAP 0000:
Start MAP on page 3-6 to perform fault isolation.
Event Data: Refer to the T11/99-017v0 document for the specific link incident record format.
Distribution: Switch Management Server Host
SANpilot
Event Log
System
Error LED
Event Log E-Mail Call-Home Sense Info Link Incident
✔