FW 07.00.00/HAFM SW 08.06.00 McDATA Sphereon 4300 Fabric Switch Installation and Service Manual (620-000171-010, April 2005)

A-34
McDATA Sphereon 4300 Fabric Switch Installation and Service Manual
Event Code: 581
Message: Implicit incident.
Severity: Major.
Explanation: An attached open systems interconnection (OSI) server recognized a condition caused by an event that occurred
at the server. The event caused an implicit Fibre Channel link incident.
Action: A link incident record (LIR) is generated and sent to the attached server using the reporting procedure defined in
T11/99-017v0 (OSI). If fault isolation at the server does not detect a failure, the problem may be due to a port
failure. Go to MAP 0000: Start MAP on page 3-6 to perform fault isolation.
Event Data: Refer to the T11/99-017v0 document for the specific link incident record format.
Distribution: Switch Management Server Host
SANpilot
Event Log
System
Error LED
Event Log E-Mail Call-Home Sense Info Link Incident
Event Code: 582
Message: Bit error threshold exceeded.
Severity: Major.
Explanation: An attached OSI server determined the number of code violation errors recognized exceeded the bit error
threshold.
Action: A LIR is generated and sent to the attached server using the reporting procedure defined in T11/99-017v0 (OSI).
If fault isolation at the server does not detect a failure, the problem may be due to a port failure. Go to MAP 0000:
Start MAP on page 3-6 to perform fault isolation.
Event Data: Refer to the T11/99-017v0 document for the specific link incident record format.
Distribution: Switch Management Server Host
SANpilot
Event Log
System
Error LED
Event Log E-Mail Call-Home Sense Info Link Incident