FW 07.00.00/HAFM SW 08.06.00 McDATA Sphereon 4300 Fabric Switch Installation and Service Manual (620-000171-010, April 2005)
A-28
McDATA Sphereon 4300 Fabric Switch Installation and Service Manual
Event Code: 445
Message: ASIC detected a system anomaly.
Severity: Informational.
Explanation: The application-specific integrated chip (ASIC) detected a deviation in the normal operating mode or operating
status of the switch.
Action: No action required. An additional event code is generated if this incident exceeds an error threshold that results in
a system event.
Event Data: Byte 0 = embedded port number. Byte 12 = detecting port.
Byte 1 = anomaly reason code. Byte 13 = connected port.
Bytes 4 - 7 = elapsed millisecond tick count. Bytes 16 and 17 = high-availability error callout #3.
Bytes 8 and 9 = high-availability error callout #1. Bytes 18 and 19 = high-availability error callout #4.
Bytes 10 and 11 = high-availability error callout #2.
Distribution: Switch Management Server Host
SANpilot
Event Log
System
Error LED
Event Log E-Mail Call-Home Sense Info Link Incident
✔
Event Code: 453
Message: New feature key installed.
Severity: Informational.
Explanation: This event occurs when a new feature key is installed from the SANpilot interface. The switch performs an IPL
when the feature key is enabled. Event data indicates which feature or features are installed.
Action: No action required.
Event Data: Byte 0 = feature description as follows: 00 - 04 = Flexport Technology, 06 = Open-system management server.
Byte 1 = feature description as follows: 06 = SANtegrity binding, 07 = OpenTrunking.
Distribution: Switch Management Server Host
SANpilot
Event Log
System
Error LED
Event Log E-Mail Call-Home Sense Info Link Incident
✔