FW 07.00.00/HAFM SW 08.06.00 McDATA Sphereon 4300 Fabric Switch Installation and Service Manual (620-000171-010, April 2005)

Event Code Tables
A-21
Event Code: 302
Message: Cooling fan propeller failed.
Severity: Major.
Explanation: Three cooling fans (out of three) failed or are rotating at insufficient angular velocity. The remaining fans are
operational. The amber LED illuminates at the rear of the power supply assembly (or assemblies) associated with
the failed fans.
Action: Replace the switch.
Event Data: The first byte of event data (byte 0) specifies the failed fan numbers (0 through 2 inclusive).
Distribution: Switch Management Server Host
SANpilot
Event Log
System
Error LED
Event Log E-Mail Call-Home Sense Info Link Incident
✔✔
Event Code: 310
Message: Cooling fan propeller recovered.
Severity: Informational.
Explanation: One cooling fan (out of three) recovered or the associated power supply assembly was replaced. All fans are
operational.
Action: No action required.
Event Data: The first byte of event data (byte 0) specifies the recovered fan number (0 through 2 inclusive).
Distribution: Switch Management Server Host
SANpilot
Event Log
System
Error LED
Event Log E-Mail Call-Home Sense Info Link Incident