FW 07.00.00/HAFM SW 08.06.00 McDATA Sphereon 4300 Fabric Switch Installation and Service Manual (620-000171-010, April 2005)
A-20
McDATA Sphereon 4300 Fabric Switch Installation and Service Manual
Fan Events (300 through 399)
Event Code: 300
Message: Cooling fan propeller failed.
Severity: Major.
Explanation: One cooling fan (out of three) failed or is rotating at insufficient angular velocity. The remaining fans are
operational. The amber LED illuminates at the rear of the power supply assembly associated with the failed fan.
Action: Replace the switch.
Event Data: The first byte of event data (byte 0) specifies the failed fan number (0 through 2 inclusive).
Distribution: Switch Management Server Host
SANpilot
Event Log
System
Error LED
Event Log E-Mail Call-Home Sense Info Link Incident
✔✔ ✔
Event Code: 301
Message: Cooling fan propeller failed.
Severity: Major.
Explanation: Two cooling fans (out of three) failed or are rotating at insufficient angular velocity. The remaining fans are
operational. The amber LED illuminates at the rear of the power supply assembly (or assemblies) associated with
the failed fans.
Action: Replace the switch.
Event Data: The first byte of event data (byte 0) specifies the failed fan numbers (0 through 2 inclusive).
Distribution: Switch Management Server Host
SANpilot
Event Log
System
Error LED
Event Log E-Mail Call-Home Sense Info Link Incident
✔✔ ✔