FW 07.00.00/HAFM SW 08.06.00 McDATA Sphereon 4300 Fabric Switch Installation and Service Manual (620-000171-010, April 2005)
Event Code Tables
A-13
Event Code: 081 (continued)
Event Data
(continued):
C = ESA security mismatch - Processing of the Exchange Security Attribute (ESA) frame detected a security
feature mismatch. The fabric binding and switch binding parameters for this switch and the attached fabric
element must agree. At the Fabric Binding and Switch Binding - State Change dialog boxes, ensure the
parameters for both fabric elements are compatible, or disable the fabric and switch binding features.
D = Fabric binding mismatch - Fabric binding is enabled and an attached fabric element has an incompatible
fabric membership list. At the Fabric Binding dialog box, update the fabric membership list for both fabric
elements to ensure compatibility, or disable the fabric binding feature.
E = Authorization failure reject - The fabric element connected to the switch through an ISL detected a security
violation. As a result, the switch received a generic reason code and set the port to an invalid attachment state.
Check the port status of the attached fabric element and clean the link’s fiber-optic components (cable and
connectors). If the problem persists, contact support personnel to report the problem.
F = Unauthorized switch binding WWN - Switch binding is enabled and an attached device or fabric element
has an incompatible switch membership list. At the Switch Binding - Membership List dialog box, update the
switch membership list for the switch and the attached device or fabric element to ensure compatibility, or disable
the switch binding feature.
11 = Fabric mode mismatch - Based on the ELP revision level, a connection was not allowed because a
McDATA switch in legacy mode is attached to a McDATA switch in Open Fabric mode, or a McDATA switch in
Open Fabric mode is attached to an OEM switch at an incorrect ELP revision level. Update the fabric mode for
one switch using the Interop Mode drop-down list at the Configure Fabric Parameters dialog box.
12 = CNT WAN extension mode mismatch - Based on switch-to-switch differences between the ELP maximum
frame sizes allowed, a connection was not allowed to a switch set to Computer Network Technologies (CNT)
wide area network (WAN) extension mode. Contact McDATA support personnel to obtain software maintenance
release 4.02.00. This release is required to correct the problem and allow McDATA switches to communicate with
CNT UltraEdge WAN Gateways.
Distribution: Switch Management Server Host
SANpilot
Event Log
System
Error LED
Event Log E-Mail Call-Home Sense Info Link Incident
✔