FW 07.00.00/HAFM SW 08.06.00 McDATA Sphereon 4300 Fabric Switch Installation and Service Manual (620-000171-010, April 2005)

4-42
McDATA Sphereon 4300 Fabric Switch Installation and Service Manual
Figure 4-36
Browser-Specific Message Box
6. Click OK to reset the configuration. The message Your changes
have been successfully activated appears.
7. The switch IP address resets to the default address of 10.1.1.10.
If the configured IP address (prior to reset) was the same as
the default address, the browser-to-switch Internet connection
is not affected and the procedure is complete.
If the configured IP address (prior to reset) was not the
same as the default address, the browser-to-switch Internet
connection drops and the SANpilot session is lost. Continue
to the next step.
8. To change the switch IP address and restart the SANpilot
interface, refer to Configure Network Information on page 2-19. To
restart the SANpilot interface using the default IP address of
10.1.1.10:
a. At the browser, enter the default IP address of 10.1.1.10 as the
Internet uniform resource locator (URL). The Enter Network
Password dialog box displays.
b. Type the default user name and password.
NOTE: The default user name is Administrator and the default
password is password. The user name and password are
case-sensitive.
c. Click OK. The SANpilot interface opens with the View panel
open and the Switch page displayed. The procedure is
complete.