FW 07.00.00/HAFM SW 08.06.00 McDATA Sphereon 4300 Fabric Switch Installation and Service Manual (620-000171-010, April 2005)
Repair Information
4-39
3. At the Download Firmware file from field:
— Select the desired firmware file from the PC hard drive using
the Browse button, or
— Type the desired firmware filename in the Download Firmware
file from field.
4. Click Send and Load Firmware. A browser-specific message box
displays (Figure 4-32).
Figure 4-32 Browser-Specific Message Box
5. Click OK to download the firmware version to the switch. The
download process takes several minutes to complete, during
which the browser is unavailable.
6. When the firmware version is downloaded to the switch and
verified, the following message box displays (Figure 4-33).
Figure 4-33 Firmware Received Message Box
7. After firmware verification, the switch performs an IML that
takes approximately 30 seconds to complete. During the IML, the
browser-to-switch Internet connection drops momentarily and
the SANpilot session is lost.
8. After the switch IML and SANpilot session logout, the following
message box displays (Figure 4-34 on page 4-40).