Unblock a Port
To unblock a switch port from the SANpilot interface:
1. When the SANpilot interface opens, the View panel and Switch
page appear as the default. At the View panel, select the Configure
option at the left side of the panel. The Configure panel opens with
the Ports page displayed (Figure 4-19 on page 4-27).
2. Click the check box for the selected port in the Blocked column to
remove the check mark and unblock the port. A blank box
indicates the port is unblocked.
3. Click Activate at the bottom of the page to save and activate the
unblocked configuration. The message Your changes to the port
configuration have been successfully activated appears.
Clean Fiber-Optic Components
Perform this procedure as directed in this publication and when
connecting or disconnecting fiber-optic cables from port optical
transceivers (if necessary). To clean fiber-optic components:
1. Obtain the appropriate tools (portable can of oil-free compressed
air and alcohol pads) from the fiber-optic cleaning kit.
2. Disconnect the fiber-optic cable from the transceiver. Use
compressed air to blow any contaminants from the connector as
shown in part A of Figure 4-20.
Keep the air nozzle approximately 50 millimeters (two inches)
from the end of the connector and hold the can upright.
Blow compressed air on the surfaces and end of the connector
continuously for approximately five seconds.
Figure 4-20 Clean Fiber-Optic Components
A
B