FW 07.00.00/HAFM SW 08.06.00 McDATA Sphereon 4300 Fabric Switch Installation and Service Manual (620-000171-010, April 2005)
Repair Information
4-23
NOTE: An optional full-volatility feature is often required at military sites
that process classified data. If the feature is enabled through the switch’s
maintenance port, a memory dump file (that possibly includes classified
Fibre Channel frames) is not included as part of the data collection
procedure.
To collect maintenance data (retrieve the dump file from the CTP
card) at the SANpilot interface:
1. When the SANpilot interface opens, the View panel and Switch
page appear as the default. At the View panel, select the Operations
option at the left side of the panel. The Operations panel opens
with the Switch page displayed.
2. Click the Maintenance and System Files tabs. The Maintenance page
displays with the System Files tab selected (Figure 4-15).
Figure 4-15 Operations Panel (Maintenance Page with System Files Tab)
3. Right-click the CTP Dump link to open a list of menu options.
4. Select the Save Target As menu option. The Save As dialog box
displays (Figure 4-16 on page 4-24).