FW 07.00.00/HAFM SW 08.06.00 McDATA Sphereon 4300 Fabric Switch Installation and Service Manual (620-000171-010, April 2005)
4-20
McDATA Sphereon 4300 Fabric Switch Installation and Service Manual
NOTE: A small form factor pluggable (SFP) optical transceiver must be
installed in the port during the test. A device can remain connected
during the test.
2. When the SANpilot interface opens, the View panel and Switch
page appear as the default. At the View panel, select the Operations
option at the left side of the panel. The Operations panel opens
with the Switch page displayed.
3. Click the Port and Diagnostics tabs. The Port page displays with
the Diagnostics tab selected (Figure 4-14).
Figure 4-14 Operations Panel (Port Page with Diagnostics Tab)
4. Type the port number to be tested in the Targeted Port Number
field.
5. At the Diagnostics Test list box, select the Internal Loopback option.
6. Click Start Port Diagnostics. The test begins and:
a. The Start Port Diagnostics button changes to a Terminate Port
Diagnostics button.