FW 07.00.00/HAFM SW 08.06.00 McDATA Sphereon 4300 Fabric Switch Installation and Service Manual (620-000171-010, April 2005)
3-62
McDATA Sphereon 4300 Fabric Switch Installation and Service Manual
Did the zone name change solve the problem and did both switches
join through the ISL to form a fabric?
NO YES
↓ The switch, associated ISL, and multiswitch fabric appear
operational. Exit MAP.
Contact the next level of support. Exit MAP.
16
A switch E_Port segmented because a build fabric protocol error was
detected.
a. Disconnect the fiber-optic jumper cable from the segmented
E_Port.
b. Reconnect the cable to the same port.
Did disconnecting and reconnecting the cable solve the problem and
did both switches join through the ISL to form a fabric?
NO YES
↓ The switch, associated ISL, and multiswitch fabric appear
operational. Exit MAP.
17
Initial machine load (IML) the switch. Refer to IML or Reset the Switch
on page 4-30.
Did the IML solve the problem and did both switches join through the
ISL to form a fabric?
NO YES
↓ The switch, associated ISL, and multiswitch fabric appear
operational. Exit MAP.
Perform the data collection procedure and contact the next level of
support. Exit MAP.
18
A switch E_Port segmented because no switch in the fabric is capable
of becoming the principal switch.
a. Notify the customer the switch will be set offline. Ensure the
system administrator quiesces Fibre Channel frame traffic
through the switch and sets attached devices offline.