FW 07.00.00/HAFM SW 08.06.00 McDATA Sphereon 4300 Fabric Switch Installation and Service Manual (620-000171-010, April 2005)
3-58
McDATA Sphereon 4300 Fabric Switch Installation and Service Manual
(hops). Fibre Channel frames may persist in the fabric longer than
timeout values allow.
Advise the customer of the problem and work with the system
administrator to reconfigure the fabric so the path between any two
fabric elements does not traverse more than three hops.
Did fabric reconfiguration solve the problem?
NO YES
↓ The switch and multiswitch fabric appear operational.
Exit MAP.
Contact the next level of support. Exit MAP.
11
As indicated by an event code 063, the Fabric Controller software
detected an:
• Intrepid 6064 Director in a multiswitch fabric that has more than
the proscribed number of ISLs.
• Intrepid 6140 Director in a multiswitch fabric that has more than
the proscribed number of ISLs.
• Other fabric element (director or switch) in a multiswitch fabric
that has more than the proscribed number of ISLs.
Fibre Channel frames may be lost or routed in loops because of
potential fabric routing problems. Advise the customer of the problem
and work with the system administrator to reconfigure the fabric so
that no director or switch elements have more than the proscribed
number of ISLs.
Did fabric reconfiguration solve the problem?
NO YES
↓ The switch and multiswitch fabric appear operational.
Exit MAP.
Contact the next level of support. Exit MAP.
12
A 070 event code indicates an E_Port detected an incompatibility with
an attached switch and prevented the switches from forming a
multiswitch fabric. A segmented E_port cannot transmit Class 2 or
Class 3 Fibre Channel traffic.