FW 07.00.00/HAFM SW 08.06.00 McDATA Sphereon 4300 Fabric Switch Installation and Service Manual (620-000171-010, April 2005)

Diagnostics
3-57
7
A minor error occurred that caused the Fabric Services database to
be re-initialized to an empty state. As a result, a disruptive fabric
logout and login occurred for all attached devices. The following list
explains the error:
Event code 011 - The Login Server database failed cyclic
redundancy check (CRC) validation.
Event code 021 - The Name Server database failed CRC
validation.
All attached devices resume operation after fabric login. Perform the
data collection procedure and return the diskette to McDATA for
analysis. Exit MAP.
8
A minor error occurred that caused the Management Server database
to be re-initialized to an empty state. As a result, a disruptive server
logout and login occurred for all attached devices. The following list
explains the error:
Event code 051 - The Management Server database failed CRC
validation.
Event code 052 - An internal operating error was detected by
the Management Server subsystem.
All attached devices resume operation after Management Server
login. Perform the data collection procedure and return the diskette to
McDATA for analysis. Exit MAP.
9
As indicated by an event code 061, a minor error occurred that
caused the Fabric Controller database to fail CRC validation and be
re-initialized to an empty state. As a result, the switch briefly lost
interswitch link capability.
All interswitch links resume operation after CTP reset. Perform the
data collection procedure and return the diskette to McDATA for
analysis. Exit MAP.
10
As indicated by an event code 062, the Fabric Controller software
detected a path to another fabric element (director or switch) in a
multiswitch fabric that traverses more than three interswitch links