FW 07.00.00/HAFM SW 08.06.00 McDATA Sphereon 4300 Fabric Switch Installation and Service Manual (620-000171-010, April 2005)
3-56
McDATA Sphereon 4300 Fabric Switch Installation and Service Manual
5
Go to the web server PC accessing the switch’s SANpilot interface.
Does the SANpilot interface appear operational?
YES NO
↓ Analysis for an Ethernet link, AC power distribution, or CTP
failure is not described in this MAP. Go to MAP 0000: Start
MAP on page 3-6. If this is the second time at this step,
contact the next level of support. Exit MAP.
6
Inspect the Fibre Channel port segmentation reason at the SANpilot
interface.
a. At the View panel, click the Port Properties tab. The View panel
opens with the Port Properties page displayed.
b. Click the port number (0 through 11) of the segmented port.
c. Inspect the Reason field for the selected port.
Is the Reason field blank or does it display an N/A message?
NO YES
↓ The switch ISL appears operational. Exit MAP.
The Reason field displays a segmentation reason message.
Tabl e 3-11 lists the reasons and associated steps that describe fault
isolation procedures.
Table 3-11 Port Segmentation Reasons and Actions
Segmentation Reason Action
Incompatible operating parameters. Go to step 13.
Duplicate domain ID. Go to step 14.
Incompatible zoning configurations. Go to step 15.
Build fabric protocol error. Go to step 16.
No principal switch. Go to step 18.
No response from attached switch (hello timeout). Go to step 19.