FW 07.00.00/HAFM SW 08.06.00 McDATA Sphereon 4300 Fabric Switch Installation and Service Manual (620-000171-010, April 2005)

3-54
McDATA Sphereon 4300 Fabric Switch Installation and Service Manual
42
Connect a Fibre Channel device to the port as directed by the
customer.
Did connection of a device to the port solve the problem?
NO YES
The switch appears operational. Exit MAP.
43
A problem exists with the fiber-optic cable, attached device, or SFP
optical transceiver. Go to step 18.
MAP 0600: Fabric, ISL, and Segmented Port Problem
Determination
This MAP describes fault isolation of fabric logout, interswitch link
(ISL), and E_Port segmentation problems. Failure indicators include:
An event code recorded at the SANpilot Event Log.
A segmentation reason associated with a Fibre Channel port at
the SANpilot interface.
1
Base product Fibre Channel ports on the Sphereon 4300 Switch can
only be configured as F_Ports or fabric loop (FL_Ports). Installation of
the full-fabric PFE key is required to configure ports as E_Ports and
enable ISL connections to other fabric elements.
Is the full-fabric PFE key installed on the switch?
NO YES
Go to step 3.
2
Does the customer desire installation of the full-fabric PFE key?
YES NO
The switch appears operational and the inability to configure
E_Ports and connect the switch to another fabric element is
acceptable to the customer. No action is required. Exit MAP.
Install the full-fabric PFE key. Refer to Install PFE Keys (Optional) on
page 2-38. Exit MAP.