FW 07.00.00/HAFM SW 08.06.00 McDATA Sphereon 4300 Fabric Switch Installation and Service Manual (620-000171-010, April 2005)
Diagnostics
3-53
39
A transmission speed conflict between the port configuration and the
SFP optical transceiver is indicated.
a. At the SANpilot interface View panel, select Configure at the left
side of the panel. The Configure panel opens with the Ports page
displayed.
b. At the Speed column, click the arrow adjacent to the list box for
the port and select a port speed as follows:
•Select 1 Gb/sec if a one gigabit per second (Gbps) optical
transceiver is installed in the port.
•Select 2 Gb/sec if a two Gbps optical transceiver is installed
in the port.
c. Click Activate to save the change. The message Your changes
to the port configuration have been successfully activated
appears.
Did reconfiguring the port speed solve the problem?
NO YES
↓ The switch appears operational. Exit MAP.
Contact the next level of support. Exit MAP.
40
A switch port state indicates No Light because a Fibre Channel
device is not attached to the port, or a problem exists with the
fiber-optic cable, attached device, or SFP optical transceiver.
Is a Fibre Channel device connected to the port?
NO YES
↓ Go to step 43.
41
Does the customer desire a device connection?
YES NO
↓ The switch appears operational and the No Light state is
acceptable to the customer. No action is required. Exit MAP.