FW 07.00.00/HAFM SW 08.06.00 McDATA Sphereon 4300 Fabric Switch Installation and Service Manual (620-000171-010, April 2005)

3-52
McDATA Sphereon 4300 Fabric Switch Installation and Service Manual
35
The switch and attached device are performing a Fibre Channel link
reset. This is a transient state. Wait approximately 30 seconds and
inspect port state and LED behavior.
Did the link recover and resume operation?
NO YES
The Fibre Channel link and switch appear operational.
Exit MAP.
Go to step 1.
36
A switch port state is inactive because the Flexport Technology
product feature enablement (PFE) key is not installed for the port
(Fibre Channel ports 4 through 11 only) or because of a transmission
speed conflict between the port configuration and the SFP optical
transceiver.
Is the inactive port a:
Base configuration port (Fibre Channel
ports 0 through 3), or an
Installed Flexport Technology port (Fibre Channel
ports 4 through 11)?
NO YES
Go to step 39.
37
Does the customer desire installation of the Flexport Technology PFE
key (ports 4 through 7 and/or ports 8 through 11)?
YES NO
The switch appears operational and the Inactive port state is
acceptable to the customer. No action is required. Exit MAP.
38
Install the Flexport Technology PFE key. Refer to Install PFE Keys
(Optional) on page 2-38.
Did installation of the key solve the problem?
NO YES
The switch appears operational. Exit MAP.