FW 07.00.00/HAFM SW 08.06.00 McDATA Sphereon 4300 Fabric Switch Installation and Service Manual (620-000171-010, April 2005)
Diagnostics
3-47
— Select the McDATA Fabric 1.0 option if the switch is
fabric-attached only to other McDATA directors or switches
that are also operating in McDATA Fabric 1.0 mode.
— Select the Open Fabric 1.0 option if the switch is
fabric-attached to directors or switches produced by other
original equipment manufacturers (OEMs) that are
open-fabric compliant.
e. Click Activate to save the change. The message Your
changes to the fabric parameters configuration have been
successfully activated appears.
Did configuring the operating mode solve the problem?
NO YES
↓ The switch appears operational. Exit MAP.
Contact the next level of support. Exit MAP.
27
A loopback (wrap) plug appears to be connected to the port and
there is no diagnostic test running. Is a loopback plug in the port
receptacle?
YES NO
↓ Contact the next level of support. Exit MAP.
28
Remove the loopback plug from the port receptacle. If directed by the
customer, connect a fiber-optic jumper cable attaching a device to the
switch.
• If the port is operational and a device is not attached, both LEDs
adjacent to the port extinguish and the port state is No Light.
• If the port is operational and a device is attached, the blue or
green LED illuminates, the amber LED extinguishes, and the
port state is Online.
Did removing the loopback plug solve the problem?
NO YES
↓ The switch appears operational. Exit MAP.
Contact the next level of support. Exit MAP.