FW 07.00.00/HAFM SW 08.06.00 McDATA Sphereon 4300 Fabric Switch Installation and Service Manual (620-000171-010, April 2005)
3-40
McDATA Sphereon 4300 Fabric Switch Installation and Service Manual
b. Click the Security tab, then click the Port Binding tab. The Port
Binding page displays.
c. Inspect entries the Port WWN column. These are WWNs
assigned to the port or Fibre Channel interface installed on the
attached device.
— If a nickname is not assigned to the WWN, the WWN is
prefixed by the device manufacturer’s name.
— If a nickname is assigned to the WWN, the nickname
appears in place of the WWN.
d. The bound WWN must be entered in the form of a raw WWN
format (XX:XX:XX:XX:XX:XX:XX:XX) or must be a valid
nickname. Ensure a valid WWN or nickname is entered.
Did configuring the WWN or nickname solve the problem?
NO YES
↓ The switch appears operational. Exit MAP.
Contact the next level of support. Exit MAP.
14
As indicated by event code 507, a Fibre Channel port failed an
internal or external loopback test.
a. At the SANpilot interface, reset each port that failed the loopback
test.
1. At the View panel, select Operations at the left side of the
panel. The Operations panel opens with the Switch and
Beacon pages displayed.
2. Click the Port tab. The Operations panel opens with the Port
and Beacon pages displayed.
3. Click the Reset tab. The Reset page displays.
4. Click the check box (checked) in the Port Reset column and
click Activate to reset the port. The message Your changes
have been successfully activated appears.
b. Perform an external loopback test for all ports that were reset.
Refer to Perform Port Diagnostic Loopback Tests on page 4-19.
Did resetting ports solve the problem?
NO YES
↓ The switch appears operational. Exit MAP.