FW 07.00.00/HAFM SW 08.06.00 McDATA Sphereon 4300 Fabric Switch Installation and Service Manual (620-000171-010, April 2005)
Diagnostics
3-39
11
A switch port is unblocked and receiving the offline sequence (OLS)
or not operational sequence (NOS) from an attached device.
Inform the customer that the attached device failed or is set offline,
and to take the appropriate corrective action. Exit MAP.
12
Install an SFP optical transceiver in the port receptacle. Refer to
RRP 1: SFP Optical Transceiver on page 5-2.
• This procedure is concurrent and can be performed while the
switch is powered on and operational.
• Verify location of the uninstalled port.
• Perform an external loopback test for the port as part of FRU
removal and replacement. Refer to Perform Port Diagnostic
Loopback Tests on page 4-19.
Exit MAP.
13
As indicated by a message or event code 080, the eight-byte
(16-digit) worldwide name (WWN) entered to configure port binding is
not valid or a nickname was used that is not configured for the
attached device. Inspect port binding parameters at the SANpilot
interface
a. At the View panel, select Configure at the left side of the panel.
The Configure panel opens with the Ports page displayed.
Not Installed Go to step 12.
Invalid Attachment Go to step 24.
Link Reset Go to step 35.
Inactive Go to step 36.
No light Go to step 40.
Segmented E_Port Go to MAP 0600.
Table 3-8 Port Operational States and Actions (Continued)
Operational State Action