FW 07.00.00/HAFM SW 08.06.00 McDATA Sphereon 4300 Fabric Switch Installation and Service Manual (620-000171-010, April 2005)

3-36
McDATA Sphereon 4300 Fabric Switch Installation and Service Manual
4
Is fault isolation being performed at the switch?
YES NO
Fault isolation is being performed at the SANpilot interface.
Go to step 7.
5
Each port has an amber LED and a blue (2 Gbps operation) or green
(1 Gbps operation) LED adjacent to the port. The amber LED
illuminates and the blue or green LED extinguishes if the port fails.
Is an amber port LED illuminated but not blinking (beaconing)?
YES NO
The switch appears operational, however a link incident or
other problem may have occurred. Go to step 16.
6
As indicated by a visual inspection, message, or event code 506, 512,
or 514, a Fibre Channel port failed and the SFP optical transceiver
must be removed and replaced. Refer to RRP 1: SFP Optical
Transceiver on page 5-2.
507 Loopback diagnostics port failure. Go to step 14.
512 SFP optical transceiver nonfatal error. Go to step 6.
514 SFP optical transceiver failure. Go to step 6.
581 Implicit incident. Go to step 17.
582 Bit error threshold exceeded. Go to step 17.
583 Loss of signal or loss of synchronization. Go to step 17.
584 Not operational primitive sequence received. Go to step 17.
585 Primitive sequence timeout. Go to step 17.
586 Invalid primitive sequence received for current link state. Go to step 17.
Table 3-7 MAP 500 Event Codes
Event
Code
Explanation Action