FW 07.00.00/HAFM SW 08.06.00 McDATA Sphereon 4300 Fabric Switch Installation and Service Manual (620-000171-010, April 2005)

Diagnostics
3-35
MAP 0500: Port Failure and Link Incident Analysis
This MAP describes fault isolation for shortwave laser small form
factor pluggable (SFP) optical transceivers, longwave laser SFP
optical transceivers, and Fibre Channel link incidents. Failure
indicators include:
An event code recorded at the SANpilot Event Log.
A link incident event code recorded at the console of an OSI
server attached to the switch reporting the problem.
One or more amber LEDs on the ports illuminate.
A port operational state message or a Failed message associated
with a port at the SANpilot interface.
1
Was an event code 080, 081, 506, 507, 512, or 514 observed at the
SANpilot Event Log?
NO YES
Go to step 3.
2
Was an event code 581, 582, 583, 584, 585, or 586 observed at the
console of an OSI server attached to the switch reporting the
problem?
YES NO
Go to step 4.
3
Tabl e 3-7 lists event codes, brief explanations of the codes, and
associated steps that describe fault isolation procedures.
Table 3-7 MAP 500 Event Codes
Event
Code
Explanation Action
080 Unauthorized worldwide name. Go to step 13.
081 Invalid attachment. Go to step 24.
506 Fibre Channel port failure. Go to step 6.