FW 07.00.00/HAFM SW 08.06.00 McDATA Sphereon 4300 Fabric Switch Installation and Service Manual (620-000171-010, April 2005)

Diagnostics
3-25
5
Either a switch-to-PC Internet link problem (Internet too busy or
IP address typed incorrectly) or a switch Ethernet port failure is
indicated.
a. Wait approximately five minutes, then attempt to login to the
switch again.
b. At the Netsite field (Netscape Navigator) or Address field
(Internet Explorer), type http://xxx.xxx.xxx.xxx, where
xxx.xxx.xxx.xxx is the IP address of the switch (obtained in
MAP 0000: Start MAP on page 3-6). The Username and
Password Required dialog box appears.
c. Type the user name and password obtained in MAP 0000: Start
MAP on page 3-6, and click OK. If the View panel does not
display, wait five minutes and perform this step again.
Does the SANpilot interface appear operational with the View panel
displayed?
NO YES
The switch-to-SANpilot PC connection is restored and
appears operational. Exit MAP.
6
A problem with another LAN-attached device may be indicated.
If the problem is associated with another switch or server, go to
MAP 0000: Start MAP on page 3-6 to isolate the problem for that
device. Exit MAP.
If the problem is associated with an unrelated device, notify the
customer and have the system administrator correct the
problem.
Did repair of an unrelated LAN-attached device solve the problem?
NO YES
The switch-to-SANpilot PC connection is restored and
appears operational. Exit MAP.
7
The IP address defining the switch to the Ethernet LAN must be
verified. A maintenance terminal (PC) and asynchronous RS-232 null
modem cable are required to verify the switch IP address. The tools