FW 07.00.00/HAFM SW 08.06.00 McDATA Sphereon 4300 Fabric Switch Installation and Service Manual (620-000171-010, April 2005)
Diagnostics
3-23
5
The CTP card failed POSTs as indicated by FRU code 02. Replace
the switch. Exit MAP.
6
A cooling fan failed POSTs as indicated by FRU code 05. Replace the
switch. Exit MAP.
7
The power supply failed POSTs as indicated by FRU code 06.
Replace the switch. Exit MAP.
8
POST/IML diagnostics detected a firmware failure as indicated by
event code 411 and performed an online dump. All Fibre Channel
ports reset after the failure and devices momentarily logout, login, and
resume operation.
Perform the data collection procedure and return the diskette to
McDATA for analysis. Exit MAP.
MAP 0300: Loss of Web Browser PC Communication
This MAP describes fault isolation of the Ethernet communication
link between a switch and a web browser PC running the SANpilot
interface. The failure indication is a Page cannot be found, Unable to
locate the server, HTTP 404 - file not found, or other similar
message.
ATTENTION ! Prior to servicing a product, determine the Ethernet LAN
configuration. Installation of products on a public customer intranet can
complicate problem determination and fault isolation.
1
Does the SANpilot interface appear operational?
NO YES
↓ The switch-to-SANpilot PC connection is restored and
appears operational. The cause may be an Ethernet adapter
reset (on the switch CTP card) in response to an error. The
connection to the web browser PC terminates briefly, then
recovers upon reset.