FW 07.00.00/HAFM SW 08.06.00 McDATA Sphereon 4300 Fabric Switch Installation and Service Manual (620-000171-010, April 2005)
3-22
McDATA Sphereon 4300 Fabric Switch Installation and Service Manual
2
Was an event code 400 or 411 observed at the SANpilot Event Log?
YES NO
↓ Analysis for the failure is not described in this MAP. Go to
MAP 0000: Start MAP on page 3-6. Exit MAP.
3
Tabl e 3-4 on page 3-22 lists event codes, brief explanations of the
codes, and the associated steps that describe fault isolation
procedures.
4
POST/IML diagnostics detected a FRU failure as indicated by event
code 400 with supplementary event data.
a. At the SANpilot Event Log, examine the first two bytes
(0 and 1) of event data associated with event code 400.
b. Byte 0 is a FRU code that indicates the failed FRU. Byte 1 is the
slot number of the failed FRU (00 for a nonredundant FRU).
Table 3-5 lists byte 0 FRU codes and associated steps that describe
fault isolation procedures.
Table 3-4 MAP 200 Event Codes
Event
Code
Explanation Action
400 Power-up diagnostic failure. Go to step 4.
411 Firmware fault. Go to step 8.
Table 3-5 MAP 200 Byte 0 FRU Codes
Byte 0 Failed FRU Action
02 CTP card. Go to step 5.
05 Fan module. Go to step 6.
06 Power supply. Go to step 7.