FW 07.00.00/HAFM SW 08.06.00 McDATA Sphereon 4300 Fabric Switch Installation and Service Manual (620-000171-010, April 2005)

Diagnostics
3-21
11
Inspect the power supply operational state at the SANpilot interface.
a. At the View panel, click the FRU Properties tab. The View panel
(FRU Properties tab) displays.
b. Inspect the Status field for the power supply.
Does the Status field display a Failed message for the power supply?
NO YES
The power supply failed. Replace the switch. Exit MAP.
The switch appears operational. Exit MAP.
MAP 0200: POST Failure Analysis
When the switch is powered on, it performs a series of power-on
self-tests (POSTs). When POSTs complete, the switch performs an
initial machine load (IML) that loads firmware and brings the unit
online. This MAP describes fault isolation for problems that may
occur during the POST/IML process.
If an error occurs, the POST/IML process continues in an attempt to
initialize the switch and bring it online. An event code 400 displays
when the switch completes the POST/IML process.
1
Ensure the switch reporting the problem is connected to facility AC
power. Inspect the switch for indications of being powered on, such
as:
At the front bezel, an illuminated PWR LED (green)
or ERR LED (amber).
Illuminated LEDs adjacent to Fibre Channel ports.
Audio emanations and airflow from cooling fans.
Does the switch appear powered on?
YES NO
An AC power distribution problem is indicated, and analysis
for the failure is not described in this MAP. Go to MAP 0100:
Power Distribution Analysis on page 3-18. Exit MAP.