Visual inspection indicates a power supply, power distribution system,
or CTP card failure. Replace the switch. Exit MAP.
8
Does the SANpilot interface appear operational?
NO YES
Go to step 11.
9
A Page cannot be found, Unable to locate the server, HTTP
404 - file not found, or other similar message appears. The message
indicates the PC cannot communicate with the switch because:
The switch-to-PC Internet link could not be established.
AC power distribution in the switch failed, or AC power was
disconnected.
The switch CTP card failed.
Continue to the next step.
10
Ensure the switch reporting the problem is connected to facility AC
power. Inspect the switch for indications of being powered on, such
as:
At the front bezel, an illuminated PWR LED (green)
or ERR LED (amber).
Illuminated LEDs adjacent to Fibre Channel ports.
Audio emanations and airflow from cooling fans.
Is a power supply or power distribution system failure indicated?
YES NO
Analysis for an Ethernet link or CTP card failure is not
described in this MAP. Go to MAP 0000: Start MAP on
page 3-6. If this is the second time at this step, contact the