FW 07.00.00/HAFM SW 08.06.00 McDATA Sphereon 4300 Fabric Switch Installation and Service Manual (620-000171-010, April 2005)

Diagnostics
3-17
28
Check FRUs for failure symptoms.
Are any amber LEDs associated with Fibre Channel ports
illuminated?
NO YES
A Fibre Channel port failure is indicated. Go to step 18 to
obtain event codes. If no event codes are found, go to MAP
0500: Port Failure and Link Incident Analysis on page 3-35.
Exit MAP.
A link incident is indicated. Go to step 18 to obtain event codes. If no
event codes are found, go to MAP 0500: Port Failure and Link
Incident Analysis on page 3-35. Exit MAP.
29
You are at the console of an open systems interconnection (OSI)
server attached to the switch reporting the problem. If an incident
occurs on the Fibre Channel link between the switch and server, a
link incident record is generated and sent to the server using the
reporting procedure defined in T11/99-017v0.
Was a link incident record generated and sent to the switch-attached
OSI server?
YES NO
Perform fault isolation at the switch. Go to step 20.
30
The link incident record provides the attached switch port number(s)
and one or more of the following event codes and messages. Record
all event codes that may relate to the reported problem.
581 - Link interface incident - implicit incident.
582 - Link interface incident - bit-error threshold exceeded.
583 - Link failure - loss of signal or loss of synchronization.
584 - Link failure - not-operational primitive sequence received.
585 - Link failure - primitive sequence timeout.
586 - Link failure - invalid primitive sequence received for the
current link state.