FW 07.00.00/HAFM SW 08.06.00 McDATA Sphereon 4300 Fabric Switch Installation and Service Manual (620-000171-010, April 2005)

Diagnostics
3-15
21
Is the switch connected to facility AC power?
NO YES
Go to step 24.
22
Connect the switch to facility AC power. Inspect the switch for
indications of being powered on, such as:
At the front bezel, an illuminated PWR LED (green)
or ERR LED (amber).
Illuminated LEDs adjacent to Fibre Channel ports.
Audio emanations and airflow from cooling fans.
Does the switch appear powered on?
YES NO
A power distribution problem is indicated. Go to step 18 to
obtain event codes. If no event codes are found, go to MAP
0100: Power Distribution Analysis on page 3-18. Exit MAP.
23
Is the green PWR LED at the switch front bezel illuminated?
NO YES
Go to step 25.
A faulty PWR LED is indicated, but switch and Fibre Channel port
operation is not disrupted. The LED is connected to CTP card
circuitry, and if this problem is a concern to the customer, the switch
must be replaced. Exit MAP.
24
Inspect the switch for indications of being powered on, such as:
At the front bezel, an illuminated PWR LED (green)
or ERR LED (amber).
Illuminated LEDs adjacent to Fibre Channel ports.
Audio emanations and airflow from cooling fans.