FW 07.00.00/HAFM SW 08.06.00 HP StorageWorks Edge Switch Release Notes (AA-RTDZG-TE/958-000284-007, March 2005)

Cable r equir ements
NOTE:
Optical cables for the Edge Switch 2/12, Edge Switch 2/12, and Edge Switch 2/32
must be ordered separately.
For cables measuring up to 500 m eters (1 Gbps) or 300 meters (2 Gbps) , use
multi-mode Fibre Channel cables. For longer cables, use single-mode Fibre Channel
cables.
Multi-mode op tical cables are connected to short-wave optical transceiver modules in
a switch. Single-mode o ptical cables are connected to long-wave optical transceiver
modules in a switch. Multi-mode cables should use 50/125 optical fibers, and
single-mode cables typically use 9/125 optical fibers for distances up to 10 km.
Verify that connectors interfacing with the Edge Switch 2/12, Edge Switch 2/24, and
Edge Switch 2/32 use LC Duplex connectors with a PC finish. In add ition, the connector
at the opposite end of the c able must be of either LC or SC type, depending on the
requirements of the connected device.
Impor t ant information
This section describes impor tant information related to the Edge Switch 2/12, Edge
Switch 2/24, and Edge Switch 2/32 .
Features not supported in this release
The following director and edge switch feature is not supported in this release:
SANtegrity Authentication
The following HAFM features are not suppor ted in this release:
SANtegrity Security Center
Group Configuration Manager
These features are described in the documentation released with firmware 07.00.00
and HAFM 08.06.00. Some of these features may be available in a future release.
8