FW 07.00.00/HAFM SW 08.06.00 HP StorageWorks Edge Switch Release Notes (AA-RTDZG-TE/958-000284-007, March 2005)

Known issues
This section descr
ibes the known issues related to the Edge Switch 2/12, Edge Switch
2/24, and Edge Swi
tch 2/32.
Certain unauthorized devices may increase response time for fabric operations
under specific conditions with the Edge Switch 2/24
When Port Binding is enabled, unauthorized devices (devices that are not set up by
the Port Binding)witholdertechnologycantransmitnumerousfabriclogin(FLOGI)
requests, which are rejected by the Edge Switch 2/24. Processing these exchanges
may increase fabric response times for activities such as fabric builds and valid FLOGI
response time for other ports.
Workaround
Remove the una
uthorized device, change the Port Binding WWN (if this device
should be authorized), or alternatively, disable Port Binding.
HSG80 transp
arent mode not supported with IBM AIX
Use of an HSG80 with IBM AIX is restricted to operating the HSG80 in Mu ltibus mode
with the Edge Switch 2 /1 2, Edge Switch 2/ 24, and Edge Switch 2/32. Transparent
mode is not supported at this time.
Workaround
None.
HSG80 transparent mode not recommended with controller in SCSI-3 mode
with HP-UX operating systems
Due to an issue with nonexistent duplicate LUNs being displayed with the HP-UX
operating systems, the HSG80 controller is restricted to SCSI-2 mode of operation
when set to Transparent failover mode.
SCSI-3 mode of operation in M ultibus failover mode is fully supported with the use of
Secure Path software, 3.0 or later versions.
Workaround
None.
26