FW 07.00.00/HAFM SW 08.06.00 HP StorageWorks Edge Switch Release Notes (AA-RTDZG-TE/958-000284-007, March 2005)
Zoning enhancement to reduce fabric congestion
In Homogeneous Fab
ric mode, an enhancement was added to reduce u nnecessary
fabric congestio
n when performing fabric-wide zoning operations that impact the Default
Zone. This enhan
cement limits the number of members allowed in the D efault Zone to
64. When the firmware detects a zoning operation that would cause the member count
in the Default Zone to exceed 64 (such as deactivating an active zone set that has more
than 64 members), the operation is aborted and the user interface (HAFM 8.6 or EWS)
displays the following message: Zoning request denied: Operation will
cause the Defa
ult Zone to exceed its limit of 64 members.
NOTE:
This limit is d
isabled when the switch parameter Suppress Zoning RSCNs on Zone set
activations check box is enabled.
Full-fabric capability for Edge Switch 2/12
Unlike other edge switch and director products, a product feature enablem ent (PFE)
key, controls Edge Switch 2/12 E_Port-to-E_Port connections. O nce the feature key is
purchased and installed, the switch can be configured for E_Port connections on any
oftheactiveports.
The feature key includes distance support. With firmware 06.00.00 and later, the Edge
Switch 2/12 ships standard with five buffer-to-buffer (BB) credits a llocated to each port.
After activation of the Full Fabric feature on a switch, every port has 12 BB Credits
allocated to support up to 12 km links at 2Gb/s speeds.
Hard zoning for Edge Switch 2 /12 and Edge Switch 2/24 switch loop ports
Firmware 06.00.00 and later extends Hard Zoning to loop (FL) p orts on Edge Switch
2/12 and Edge Switch 2/24. Previously, zoning on FL ports was regulated in software.
HP StorageWorks Edge Switch release notes
25