FW 07.00.00/HAFM SW 08.06.00 HP StorageWorks Edge Switch Release Notes (AA-RTDZG-TE/958-000284-007, March 2005)

Thefeatureconfiguresaswitchordirectorsothatnoframedataisstoredafterapower
off. Without Full Volatility, if the switch or director experiences a fault condition, a
dump of the embedded m emory space is captured into nonvolatile memory. This dump
retains the last 30 frames transmitted from and last four frames transmitted to the
embedded por t. With Full Volatility installed, this dump does not occur when a fault
condition occurs. Although this lim its the amount of diagnostic information available
for p otential problem resolution, the vast majority of problems are typically resolved
without the dump files.
Contact your sales representative to purchase a feature key for Full Volatility.
CLI threshold alerts
With firmware 0
6.00.00 and later, the CLI allows you to set and monitor Throughput
Threshold Alerts (TTAs).
CLI show.even
tLog command
With firmware 06.00.00 and later, the CLI show.eventLog command has been
enhanced. The command now displays a Link Incident log and Event log.
MIHPTO value
With firmware 06.00.00 and later, the internal Missing Interrupt Handler Primary Time
Out (MIHPTO) value has been changed from 15 seconds to 3 minutes.
EWS enhancements
With firmware 06.00.00 and later, EWS enhancements include support for managing
the SANtegrity Binding feature and Enterprise Fabric mode, and providing the Link
Incident log and the Open Trunking log.
Preferred Path support
With firmware 07.00.00 and later, this allows users who are not using HAFM to
configure preferred data paths through the EWS interface. A preferred path is an ISL
data path between multiple fabric elements (directors and switches) that users can
configure using the source and exit ports of the origination fabric element, and the
domain I D of the destination fabric element.
HP StorageWorks Edge Switch release notes
23