FW 07.00.00/HAFM SW 08.06.00 HP StorageWorks Edge Switch Release Notes (AA-RTDZG-TE/958-000284-007, March 2005)

Firmware 05.03.01-01 is available for the Edge Switch 2/24, a nd firmware
05.05.01-01 is available for the Edge Switch 2/12. These versions are installed only
ontheEdgeSwitch2/24andEdgeSwitch2/12,andonlywhentheseswitchesare
placed in a M-Series SAN running 05.02.00 firmware. A co py of these versions of
firmware, are contained on the HP StorageWorks edge switch documentation and
firmware CD (Part Number 524-000001-005).
Reinstalling feature licenses
Feature licen
ses (or keys) must be reinstalled after performing a factory reset on a
director to r
egain use of the licensed features (e.g., SANtegrity Binding).
Disconnecting the null modem cable
Always log out and disconnect the null modem cable from the serial maintenance port
when not in use or when the switch is reset.
CTP controls port lights
Port lights on the edg e switch and director products are controlled by the CTP
functionality. Certain activities such as firmware updates, IPLing the CTP, or switching
over to the backup CTP (director) can cause these port lights to extinguish momentarily
until control is reasserted by the CTP. The actual Fibre Channel traffic is not affected
during the
se times.
Ethernet switch suppor t
With firmware 06.00.00 and later, customers can now connect the management
port on edg e switches and directors to Ethernet switches or hubs. Prior to firmware
06.00.00, only connections to Ethernet hubs were qualified and supported.
Full Volatility
Full Volatility is an optional feature of firmware 06.00.00 and later that is enabled
with a f
eature key. The Full Volatility feature is designed to support high-security
environments, which require that customer data not be retained by the edge switch or
director after power off.
22