FW 07.00.00/HAFM SW 08.06.00 HP StorageWorks Edge Switch Release Notes (AA-RTDZG-TE/958-000284-007, March 2005)

Zone FlexP ar feature
Because zoning is m
anaged on a fabric-wide basis, all switches and directors in the
fabric must maint
ain the same zoning configuration. This configuration is maintained
automatically through the Fibre Channel protocol.
To keep this information current, RSCN messages are sent through the fabric to inform
attached devices when zoning changes occur, when devices become available, or
when devices become unavailable. In the case where devices become available or
unavailable, RSCNs are sent only to the devices in the same zone. Zoning changes,
however, trigger RSCNs to be sent to all of the devices in the fabric. As fabrics grow
larger and larger, the quantity of RSCNs from zoning changes can create congestion
and disrupt devices, causing them to pause normal activity to determine the status
of the other devices. This can occur even if the new device is not zoned to talk to
the other devices in the fabric.
WiththeZoneFlexParfeatureenabled,RSCNmessagesforazoningchangeare
handled like RSCNs for availability/unavailability changes. Specifically, RSCNs are
restricted to only those devices sha ring at least one common zone with the device that
changed. This way, only devices that are impacted by the change in c onnectivity
receive RSCNs.
The Zone FlexPar feature is available in both O pen Fabric 1.0 and Homogeneous
Fabric 1.0 Interop modes, as well as in environments with loop-attached devices. In
Homogeneous Fabric 1.0 mode, the default zone is treated like any other zone, and
RSCNs are sent only to the affected devices if the default zone is enabled or disabled.
A PFE key is not required for the Zone FlexPa r feature, and it can be enabled or
disabled through CLI for a specific switch. When upgrading to firmware 07.00.00
or installing a new switch with firmware 07.00.00 the feature is enabled by default,
allowing it to work immediately. If the Zone FlexPar feature is not enabled on all
switches in the fabric, the restricted RSCN distribution only applies for devices attached
to switches with the feature enabled.
Enhanced SANtegrity Security Suite
SANtegrity Security Suite enhanced features include authentication suppor t for device
login, interswitch connections and management interfaces. The Secure Access features
are included as a standard part of the SANtegrity Security Suite in firmware 07.00.00.
Standard features
The following SANtegrity features do not require a license or SANtegrity Binding.
CHAP Authentica tion for HAFM/SWAPIThisprovidesauthentication
of connections from the HAFM appliance ser vice processor and SWA PI Direct
Connect. This ensures that requested HAFM management sessions or SWAPI
Direct Connect sessions are from a trusted source.
16