FW 07.00.00/HAFM SW 08.06.00 HP StorageWorks Edge Switch Release Notes (AA-RTDZG-TE/958-000284-007, March 2005)

NOTE:
The warning message is displayed when downgrading any model from 06.02.00, but
only applies to downgrade operations for the Director 2/140.
Firmware downgrades should not be performed using EWS and Internet Explorer
v5.00.3315.1000x. If this operation is performed, the download operation may not
complete and may eventually time-out leaving the switch with the p revious version of
firmware.
HAFM upgrade required for firmware version 07.xx.xx
To upgrade to firmware 07.00.00-84, you must first upgrade the H A FM software
to 07.01.00-9 minimum, if you are using the notebook HAFM server to manage the
director or edge switch. The HAFM software is contained on the HP StorageWorks
ha-fabric manager documentation and software C D (Part N umber 516-000024-820).
An upgrade kit to HAFM 07.01.00-9 is also available, Par t Number 320908-B22, for
owners of license for previous versions. This HAFM upgrade is also available on the
following HP web site: h
ttp://h18006.www1.hp.com/storage/saninfrastructure.html
If you are using the 1U rack-mount HAFM appliance to ma nage the director or edge
switch, the minimum HA FM version required is 07.02.00-9, which is the minimum
version installed. This HAFM software is contained on the HP StorageWorks ha-fabric
manager documentation and software CD (Part Number 516-000024-720).
The previous minimum versions of HAFM allow you to manage directors or edge
switches running 07.00.00-84 firmware, but to be able to use all the new features and
enhancements, you need to upgrade HAFM to 08.06.00, which runs only on the
1U rack-mount HAFM appliance.
As an alternative, you can perform the firmware upgrade directly to the director or edge
switch using their EWS.
Please contact your local HP technical resource if you nee d to obtain a new HAFM
version.
Please contact your local HP technical resource to confirm compatibility with devices
in your SAN before upgrading to this firmware version.
For more information on upgrading software versions, refer to the HP StorageWorks
HA-Fabric Manager User Guide. Thefeaturesofthissoftwareversionaredetailedin
the acc ompanying manuals listed in section Other edge switch do cumentation.
HP StorageWorks Edge Switch release notes
15