FW 07.00.00/HAFM SW 08.06.00 HP StorageWorks Edge Switch Release Notes (AA-RTDZG-TE/958-000284-007, March 2005)
Upgrades and downgrades are supported only from one major release to the next, such
as from 06.xx.xx to 07.00.00-84. If EWS is used for upgrades and downgrades, and
this rule is not followed, errors occur and there may be a disruption to a ttached devices.
Downgradingtorelease6.0withthePreferredPathfeatureconfiguredcouldcauseloss
of this function. H P recommends that Preferred Path be disabled before downgrading.
To do this, deselect the check box for Enable Preferred Path in the Configure
Preferred Paths dialog box.
NOTE:
The Director 2/140 and the Edge Switch 2/24 cannot be downgraded earlier than
04.01.00, and the Edge Switch 2/12 cannot be downgraded earlier than 05.05.00.
Downgrades directly to 05.03. 01 from 06.xx.xx is not concurrent when the
second-generation Edge Switch 2/24 is configured in O pen Fabric operating
mode. In other words, downgrades in Open Fabric mode cannot be done with the
second-generation Edge Switch 2/24 online without disrupting port operations. Since
second-generation Edge Switch 2/24 switches cannot be downgraded earlier than
05.03.01, they must be configured in Homogeneous Fabric Interoperability
mode to remain concurrent. If this process is not followed, I/O through the switch may
be significantly disrupted or stopped. Recovery for this situation is accomplished by
reactivating the current zone set.
If you are installing a new or replacement second-generation Edge Switch 2/12 or Edge
Switch 2/24 into an existing 05.xx.xx fabric, HP recommends that you downgrade
the unit before installing it into the fabric.
Downgrading to 05.05.00 is supported only on first-generation Edge Switch 2/12
switches. Second-generation Edge Switch 2/12 switches can be downgraded only to
05.05.01. Second-generation Edge Switch 2/24 switches can be downgraded only
to 05.03.01.
If a Director 2/140 in a multiswitch fabric is downgraded earlier than 06.02.00, ISLs
could becom e segm ented if there are any other switches in the fabric operating with
a firmware version earlier than 06.01.00. To prevent this situation, downgrade all
Director 2/140s in the fabric to 06.01.00 before downgrading any products in the
fabric to 05.xx.xx. This problem only exists with Director 2/140s in the fabric. HAFM
displays a warning message if a downgrade from 06.02.00 is at tempted, but you can
continue with the downgrade if desired.
14