FW 07.00.00/HAFM SW 08.06.00 HP StorageWorks Edge Switch Element Manager User Guide (AA-RS2HD-TE, March 2005)
Edge Switch Element Manager user guide 91
Configure Ports Procedure (Open Systems Management Style)
NOTE: This procedure applies only to the Edge Switch 2/32. Open Systems Management Style
(OSMS) is not available on the Edge Switch 2/24.
To configure Edge Switch 2/32 ports in Open Systems management style, use the following steps:
1. Select Configure > Ports. The Configure Ports dialog box appears.
Figure 29 Configure Ports dialog box (Open Systems Management Style)
Ports are numbered from 0 through 31.
2. Click a Name box and type a name that reflects the end device connected through the port.
For example, use XYZ server. The XYZ is the brand name of the server.
3. Block or unblock operation for a port by clicking the check box in the Blocked column. When
a check mark displays, the port is blocked.
4. Enable or disable extended distance buffering for the port by clicking the check box in the
10-100 km column. When a check mark displays, extended distance buffering is enabled.