HP StorageWorks HSG80 ACS Solution Software V8.8 for Linux X86 Installation and Configuration Guide (AA-RV1LA-TE, March 2005)
FC Configuration Procedures
133HSG80 ACS Solution Software V8.8 for Linux X86 Installation and Configuration Guide
Configuring Controller Settings
5. Set the SCSI version to SCSI-3 using the following command:
SET THIS SCSI_VERSION=SCSI-3
6. Set the topology for the controller. If both ports are used, set topology for both
ports:
SET THIS PORT_1_TOPOLOGY=FABRIC
SET THIS PORT_2_TOPOLOGY=FABRIC
If the controller is not factory-new, it may have another topology set, in which
case these commands result in an error message. If this happens, first take
both ports offline, then reset the topology:
SET THIS PORT_1_TOPOLOGY=OFFLINE
SET THIS PORT_2_TOPOLOGY=OFFLINE
SET THIS PORT_1_TOPOLOGY=FABRIC
SET THIS PORT_2_TOPOLOGY=FABRIC
Restarting the Controller
7. Restart the controller, using the following command:
RESTART THIS
It takes about a minute for the CLI prompt to come back after a RESTART
command.
Setting Time and Verifying All Commands
8. Set the time on the controller by entering the following syntax:
SET THIS TIME=DD-MMM-YYYY:HH:MM:SS
9. Use the FRUTIL utility to set up the battery discharge timer. Enter the
following command to start FRUTIL:
RUN FRUTIL
When FRUTIL asks if you intend to replace the battery, answer Y:
Do you intend to replace this controller's cache battery? Y/N
[N] Y
FRUTIL prints out a procedure, but does not give you a prompt. Ignore the
procedure and press Enter.