HP StorageWorks HSG80 ACS Solution Software V8.8 for OpenVMS Installation and Configuration Guide (AA-RV1PA-TE, March 2005)
FC Configuration Procedures
144 HSG80 ACS Solution Software V8.8 for OpenVMS Installation and Configuration Guide
Configuring a RAIDset
1. Create the RAIDset by adding its name to the controller's list of storagesets
and by specifying the disk drives it contains. Optionally, you can specify
RAIDset switch values:
ADD RAIDSET RAIDSET-NAME DISKNNNNN DISKNNNNN DISKNNNNN SWITCHES
Note: See the ADD RAIDSET command in the
HP StorageWorks HSG60 and HSG80
Array Controller and Array Controller Software Command Line Interface (CLI)
Reference Guide
for a description of the RAIDset switches.
2. Initialize the RAIDset, specifying any desired switches:
INITIALIZE RAIDSET-NAME SWITCH
Note: HP recommends that you allow initial reconstruct to complete before allowing
I/O to the RAIDset. Not doing so may generate forced errors at the host level. To
determine whether initial reconstruct has completed, enter SHOW RAIDSET FULL.
See “Specifying Initialization Switches” on page 77 for a description of the
initialization switches.
3. Verify the RAIDset configuration:
SHOW RAIDSET-NAME
4. Assign the RAIDset a unit number to make it accessible by the hosts. See
“Assigning Unit Numbers and Unit Qualifiers” on page 147.
For example:
The commands to create RAID1, a RAIDset with three members (DISK10000,
DISK20000, and DISK10100) and to initialize it with default values:
ADD RAIDSET RAID1 DISK10000 DISK20000 DISK30000
INITIALIZE RAID1
SHOW RAID1
Configuring a Striped Mirrorset
1. Create, but do not initialize, at least two mirrorsets.
See “Configuring a Mirrorset” on page 143.