HP StorageWorks HSG80 ACS Solution Software V8.8 for Linux X86 Installation and Configuration Guide (AA-RV1LA-TE, March 2005)
FC Configuration Procedures
132 HSG80 ACS Solution Software V8.8 for Linux X86 Installation and Configuration Guide
■ "Verifying Installation", page 137
1. Enter a
SHOW THIS command to verify the node ID:
SHOW THIS
See "Worldwide Names (Node IDs and Port IDs)", page 52, for the location of
the sticker.
The node ID is located in the third line of the
SHOW THIS result:
HSG80> show this
Controller:
HSG80 ZG80900583 Software V8.8, Hardware E11
NODE_ID = 5000-1FE1-0001-3F00
ALLOCATION_CLASS = 0
If the node ID is present, go to step 5.
If the node ID is all zeroes, enter the node ID and checksum, which are
located on a sticker on the controller enclosure. Use the following syntax to
enter the node ID:
SET THIS NODE_ID=NNNN-NNNN-NNNN-NNNN nn
Where: NNNN-NNNN-NNNN-NNNN is the node ID and nn is the checksum.
2. If the controller is not new from the factory, enter the following command to
take it out of any failover mode that may have been previously configured:
SET NOFAILOVER
If the controller did have a failover mode previously set, the CLI may report
an error. Clear the error with this command:
CLEAR_ERRORS CLI
3. Enter the following command to remove any previously configured
connections:
SHOW CONNECTIONS
A list of named connections, if any, opens.
4. Delete these connections by entering the following command:
DELETE !NEWCON01
Repeat the Delete command for each of the listed connections. When
completed, no connection opens.