HP StorageWorks Fabric OS 5.X Diagnostics and System Error Messages Reference Guide (AA-RVHZB-TE, September 2005)

Fabric OS 5.x diagnostics and system error messages reference guide 391
Recommended Action
No action is required.
Severity
INFO
TRCE-1007
Message
Probable Cause
Indicates that the active CP is unable to alert the standby CP of a change in trace status. This message is
only applicable to the Core Switch 2/64, SAN Director 2/128, and 4/256 SAN Director.
Recommended Action
This message is often transitory. Wait a few minutes and try the command again.
If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the
supportSave command and contact your switch service provider.
Severity
ERROR
TRCE-1008
Message
Probable Cause
Indicates that the active CP is unable to read stored trace parameters.
Recommended Action
Run the haFailover command to switch to the standby CP. Once the fail over is complete, then reboot the
new standby CP.
Run traceFtp to set up and enable automatic FTP transfers of trace files.
If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the
supportSave command and contact your switch service provider.
Severity
CRITICAL
TRCE-1009
Message
<timestamp>, [TRCE-1007], <sequence-number>,, ERROR, <system-name>,
Notification of this CP has failed. Parameters temporarily out of
synch with other CP.
<timestamp>, [TRCE-1008], <sequence-number>,, CRITICAL,
<system-name>, Unable to load trace parameters.
<timestamp>, [TRCE-1009], <sequence-number>,, ERROR, <system-name>,
Unable to alert active CP that a dump has occurred.