HP StorageWorks Fabric OS 5.X Diagnostics and System Error Messages Reference Guide (AA-RVHZB-TE, September 2005)

Fabric OS 5.x diagnostics and system error messages reference guide 273
Recommended Action
No action is required.
Severity
INFO
HIL-1505
Message
Probable Cause
Indicates that temperatures in the system have risen above the warning threshold.
Recommended Action
Run the tempShow command to monitor switch temperatures. Refer to the hardware reference manual for
the temperature range of your switch.
Run the fanShow command to verify all the fans are working properly.
Make sure that the area is well ventilated and that the room temperature is within operational range of
your switch. Refer to the hardware reference manual for your switch for the operational temperature range.
Severity
WARNING
HIL-1506
Message
Probable Cause
Indicates that temperatures in the system have risen above the critical threshold.
Recommended Action
Run the tempShow command to monitor switch temperatures. Refer to the hardware reference manual for
the temperature range of your switch.
Run the fanShow command to verify all the fans are working properly.
Replace any deteriorating fan FRUs.
Make sure that the area is well ventilated and that the room temperature is within operational range of
your switch. Refer to the hardware reference manual for your switch for the operational temperature range.
Severity
CRITICAL
<timestamp>, [HIL-1505], <sequence-number>,, WARNING,
<system-name>, High temperature (<measured temperature> C) exceeds
environmental specifications.
<timestamp>, [HIL-1506], <sequence-number>,, CRITICAL,
<system-name>, High temperature (<measured temperature> C) exceeds
system temperature limit. System will shut down within 2 minutes.