HP StorageWorks Fabric OS 5.0.5c Release Notes (AA-RW1WE-TE, February 2007)

Fabric OS 5.0.5b fixes
Table 3 lists improvements included in Fabric OS 5.0.5b.
Table 3 Fabric O
S 5.0.5b closed defects
Closed Defec ts
Inserting unsupported FC4-48 blade into a pre-Fabric OS v5.2 chassis causes FAULTY(1)
error that will not clear with blade removal. HAsync is dropped, and an active CP reboot
is required to recover . If not upgrading to this Fabric OS 5.0.5b release the workaround
istoscheduleaconvenienttimetoreboottheactiveCP.
HBA occasionally may not log into a 4Gb switch during auto topology discovery. If not
upgrading to th is Fabric OS 5.0.5b release the workaround is to use portCfgGPort
tolocktheswitchinGportmode. Toreestablishthelinkontheaffectedport,issue
portDisable and portEnable.
Switch panics with Failure Detection (FDET) when a Linux host is connected, affecting the
SAN Switch 2/32, SAN Director 2/128, SAN Switch 2/8V and SAN Switch 2/16V
platforms.
A phantom device on an L-port disappears after HAfailover/hareboot, and a private device
is no longer in the name server database, affecting the SAN Switch 2/32, Core Switch
2/64, SA
N Director 2/128, SAN Switch 2/8V and SAN Switch 2/16V platforms. If not
upgrad
ingtothisFabricOS5.0.5breleasetheworkaroundistoissuetheportdisable
and por
tenable commands.
Specific HBA behavior causes a memory leak and the switch runs out of memory and
reboots.
Switch panics with time service daemon (tsd) core dump.
Zoning change fails with message: unabortable internal zoning transaction.
Zoning change fails with message: unabortable internal zoning transaction.
The Web Tools GUI hangs upon invoking fabric wide polling when there is no IP connection
between the We b Tools proxy switch and the other switches in the fabric.
With
out displaying an error message, a hardware ASIC failure causes performance
degradation on a 4/256 SAN Director, or a switch fault on other 4Gb switches. If not
upg
rading to this Fabric OS 5.0.5b release the workaround is to replace the faulted blade.
During stress testing, after fastboot on a fully-loaded 4/256 SAN Director a few E_ports
and F_ports may stay in Mod_Val mode. If not upgrading to this Fabric OS 5.0.5b release
the workaround is to disable and enable the port that is stuck in the Mod-Val state.
12