Fabric OS 5.x MIB reference guide 171
swFwCustBufSize
OID 1.3.6.1.4.1.1588.2.1.1.1.10.2.1.12
Description A customizable buffer size value for a Fabric Watch classArea combination.
swFwThLevel
OID 1.3.6.1.4.1.1588.2.1.1.1.10.2.1.13
Description swFwThLevel is used to point to the current level for classArea values. It is either default or
custom.
Note For a read operation, the return value is either 2 (swFwDefault) or 3 (swFwCustom). 1
(swFwReserved) is obsolete.
If the write operation sets the variable to 2 (swFwDefault), the following default
configuration variables are used for the Fabric Watch classArea combination:
• swFwDefaultUnit
• swFwDefaultTimebase
• swFwDefaultLow
• swFwDefaultHigh
• swFwDefaultBufSize
If the write operation sets the variable to 3 (swFwCustom), the following custom
configuration variables are used for the Fabric Watch classArea combination:
• swFwCustUnit
• swFwCustTimebase
• swFwCustLow
• swFwCustHigh
• swFwCustBufSize
swFwWriteActVals
OID 1.3.6.1.4.1.1588.2.1.1.1.10.2.1.14
Description Applies or cancels the alarm value changes.
Note For a read operation, the return value is always swFwCancelWrite.
The following custom alarm variables can be modified:
• swFwCustChangedActs
• swFwCustExceededActs
• swFwCustBelowActs
• swFwCustAboveActs
• swFwCustInBetweenActs
Changes to these custom alarm variables can be saved by setting this variable to
swFwApplyWrite.
Changes to these custom alarm variables can be removed by setting this variable to
swFwCancelWrite.
swFwDefaultChangedActs
OID 1.3.6.1.4.1.1588.2.1.1.1.10.2.1.15
Description Default action matrix for changed event.