HP StorageWorks Fabric OS 5.x MIB Reference Guide (AA-RVHXB-TE, September 2005)

Fabric OS 5.x MIB reference guide 169
The other table, swFwThresholdTable, contains individual threshold information such as name, label,
last event, and so forth. The thresholds are contained in SwFwThresholdEntry.
swFwFabricWatchLicense
OID 1.3.6.1.4.1.1588.2.1.1.1.10.1
Description If the license key is installed on the switch for Fabric Watch, the return value is
swFwLicensed; otherwise, the value is swFwNotLicensed.
swFwClassAreaTable
OID 1.3.6.1.4.1.1588.2.1.1.1.10.2
Description The table of classes and areas.
swFwClassAreaEntry
OID 1.3.6.1.4.1.1588.2.1.1.1.10.2.1
Description An entry of the classes and areas.
Index swFwClassAreaIndex
swFwClassAreaIndex
OID 1.3.6.1.4.1.1588.2.1.1.1.10.2.1.1
Description This index represents the Fabric Watch classArea combination.
swFwWriteThVals
OID 1.3.6.1.4.1.1588.2.1.1.1.10.2.1.2
Description This applies or cancels the configuration value changes.
Note For a read operation, the return value is always swFwCancelWrite.
The following custom configuration variables can be modified:
• swFwCustUnit
• swFwCustTimebase
• swFwCustLow
• swFwCustHigh
• swFwCustBufSize
Changes to these custom configuration variables can be saved by setting this variable to
swFwApplyWrite; they can be removed by setting this variable to swFwCancelWrite.
swFwDefaultUnit
OID 1.3.6.1.4.1.1588.2.1.1.1.10.2.1.3
Description A default unit string name, used to identify the unit of measure for a Fabric Watch
classArea combination. For example:
• C = environment (class), temperature (area).
• RPM = environment (class), fan (area).