HP StorageWorks Fabric OS 5.x MIB Reference Guide (AA-RVHXB-TE, September 2005)

Fabric OS 5.x MIB reference guide 159
Any or all of the trap recipients can be configured to send a trap for the associated
community string. The maximum number of trap recipients that can be configured is six. If
no trap recipient is configured, no traps are sent.
The trap recipient IP address should be part of the Access Control List for Fabric OS 2.6.1,
3.1, and 4.x (see the agtCfgSet command).
swAgtTrapSeverityLevel
OID 1.3.6.1.4.1.1588.2.1.1.1.4.11.1.4
Description The trap severity level associated with swAgtTrapRcp. The trap severity level, is set in
conjunction with the event’s severity level. When an event occurs, if its severity level is at
or below the set value, the SNMP trap is sent to configure trap recipients. The severity
level is limited to particular events. If a new value is set successfully, it takes effect
immediately.
Note This object obsoletes swEventTrapLevel.
Fibre Channel port group
This group contains information about the physical state, operational status, performance, and error
statistics of each Fibre Channel port on the switch. A Fibre Channel port is one that supports the Fibre
Channel protocol, such as F_Port, E_Port, U_Port, or FL_Port.
swFCPortCapacity
OID 1.3.6.1.4.1.1588.2.1.1.1.6.1
Description The maximum number of Fibre Channel ports on this switch. It includes U_Port, F_Port,
FL_Port, and any other types of Fibre Channel port.
Note The valid values are as follows:
8 for the SAN Switch 2/8-EL and SAN Switch 2/8V
• 12 for Brocade 4Gb SAN Switch for HP p-Class BladeSystem
16 for the 4/8 SAN Switch, 4/16 SAN Switch, SAN Switch 2/16, and SAN Switch
2/16V
32 for the SAN Switch 2/32 and SAN Switch 4/32
• 64 for the Core Switch 2/64
• 128 for the SAN Director 2/128
• 256 for the 4/256 SAN Director
swFCPortTable
OID 1.3.6.1.4.1.1588.2.1.1.1.6.2
Description A table that contains configuration and service parameters of the port, one entry for each
switch port.
swFCPortEntry
OID 1.3.6.1.4.1.1588.2.1.1.1.6.2.1
Description An entry containing the configuration and service parameters of the switch port.
Index swFCPortIndex