HP StorageWorks Fabric OS 5.x Fabric Watch Administrator Guide (AA-RVJ0B-TE, September 2005)

68 Default threshold values
SFP class
Table 27 provides default settings for areas in the SFP class.
Telnet Violations Monitors telnet
violations
Unit: violation(s)
Time Base: minute
Low: 1
High: 2
Buffer: 0
Changed: 0
Below: 0
Above: 3
In-Between: 0
Informative
Informative
Out_of_range
In_range
TS Out of Sync Monitors
instances in which
the timestamp is
out of sync
Unit: violation(s)
Time Base: minute
Low: 1
High: 2
Buffer: 0
Changed: 0
Below: 0
Above: 3
In-Between: 0
Informative
Informative
Out_of_range
In_range
WSNMP
Violations
Monitors
WSNMP
violations
Unit: violation(s)
Time Base: minute
Low: 1
High: 2
Buffer: 0
Changed: 0
Below: 0
Above: 3
In-Between: 0
Informative
Informative
Out_of_range
In_range
Table 26 Security class threshold defaults (continued)
Area Description Default threshold
settings
Default alarm
settings
Threshold
state
Table 27 SFP Class Threshold Defaults
Area Description Default Threshold
Settings
Default Alarm
Settings
Threshold
State
Current Monitors SFP
current
Unit: mA
Time Base: none
Low: 0
High: 50
Buffer: 1
Changed: 0
Below: 1
Above: 1
In-Between: 0
Informative
Out_of_range
Out_of_range
Informative
Receive Power Monitors receive
power in µWatts
Unit: µWatts
Time Base: none
Low: 0
High: 5000
Buffer: 25
Changed: 0
Below: 1
Above: 1
In-Between: 0
Informative
Out_of_range
Out_of_range
Informative
Supply
Voltage
Monitors SFP
electrical force in
volt(s)
Unit: mV
Time Base: none
Low: 3150
High: 3600
Buffer: 10
Changed: 0
Below: 1
Above: 1
In-Between: 0
Informative
Out_of_range
Out_of_range
Informative
Temperature Monitors SFP
Temperature
Unit: degrees C
Time Base: none
Low: -10
High: 85
Buffer: 3
Changed: 0
Below: 1
Above: 1
In-Between: 1
Informative
Out_of_range
Out_of_range
Normal
Transmit
Power
Monitors transmit
power in µWatts
Unit: µWatts
Time Base: none
Low: 0
High: 5000
Buffer: 25
Changed: 0
Below: 1
Above: 1
In-Between: 0
Informative
Out_of_range
Out_of_range
Normal