HP StorageWorks Fabric OS 5.X Diagnostics and System Error Messages Reference Guide (AA-RVHZB-TE, September 2005)

88 Introduction to System Messages
Viewing the system messages with page breaks
This procedure is valid for HP StorageWorks Fabric OS 5.x switches.
To display the system message log, with page breaks:
1. Log in to the switch as admin.
2. At the command line, enter the errShow command:
Clearing the system message log
This procedure is valid for HP StorageWorks Fabric OS 5.x switches.
To clear the system message log for a particular switch instance:
1. Log in to the switch as admin.
2. Enter the errClear command to clear all messages from memory
The following example shows how to clear the system message log:
Responding to a system message
This section provides procedures on gathering information on system messages.
Looking up a system message
Error messages are arranged in this manual alphabetically. To look up an error message, copy down the
appropriate module number and the error code and compare this with the Table of Contents to determine
the location of the information for that error message.
Information provided by this book is as follows:
Module and code name for the error
Message text
Probable cause
Recommended action
Message severity
switch:admin> errShow
Version: 5.0.1
2004/07/28-17:04:59, [FSSM-1002], 1,, INFO, switch, HA State is in
sync
Type <CR> to continue, Q<CR> to stop:
2004/07/28-17:04:59, [FSSM-1003], 2,, WARNING, switch, HA State out
of sync
Type <CR> to continue, Q<CR> to stop:
2004/07/28-17:04:51, [EM-1055], 3,, WARNING, switch, Media 27: Port
media incompatibl
e. Reason: Configured port speed.
Type <CR> to continue, Q<CR> to stop:
switch:admin> errclear
switch:admin>